This type of power station has very high energy losses due to great heat loss in the boiler and condensor. the following equation is used to calculate power station efficiency:

Thermal efficiency =Mechnical.energyto.turbineshaftHeat.of.coal.combustion

the above can be re-written as follows:

ηthermal=Mechnical.energyHeat.of.coal

The above generally works out to ±30% for steam power stations.

you can further calculate overall efficiency as follows:

ηoverall=Heat.equivelence.of.Electric.power.outputHeat.of.coal.used

the above can be re-written as follows:

ηoverall=ηElectrical×ηThermal

The above generally works out to ±29% ( 1% loss at the generator ) for steam power stations.